Miscellaneous Settings - Omron MX2 User Manual

200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for MX2:
Table of Contents

Advertisement

"B" Group: Fine Tuning Functions

3-6-19 Miscellaneous Settings

Func.
Code
B082
Start frequency
B084
Initialization mode (parame-
ters or trip history)
B085
Initial Data selection
B087
STOP/RESET key enable
b090
Dynamic braking usage ratio
B092
Cooling fan control
B093
Clear elapsed time of cooling
fan
The miscellaneous settings include scaling factors, initialization modes, and
others. This section covers some of the most important settings you may need
to configure.
Start frequency adjustment: B082 – When the inverter starts to run, the output
frequency does not ramp from 0Hz. Instead, it steps directly to the start fre-
quency (B082), and the ramp proceeds upward from there.
Initialization related: B084, B085, B094, B180 – These functions allow you to
restore the factory default settings. Please refer to 6-3 Restoring Factory
Default Settings on page 245.
Stop key enable function: B087 – This function allows you to decide whether
the stop key on the integrated operator is enabled or not.
Dynamic Braking related functions: B090, B095, B096, – These parameters are
for using the internal brake chopper so to get more regeneration torque of the
motor.
Cooling Fan Control: B092 – You can select the performance of the cooling fan
(if your inverter model includes a fan). This function controls whether the cool-
ing fan stops or keeps on running after the inverter stops the motor. This can
result in an additional energy saving and extends fan life.
"B" Function
Name
Sets the starting frequency for the
inverter output, range is 0.10 to
9.99 Hz
Select initialized data, five option
codes:
00
Initialization disabled
01
Clears Trip history
02
Initializes all Parameters
03
Clears Trip history and initial-
izes all parameters
04
Clears Trip history and initial-
izes all parameters and
EzSQ program
Select initial data for initialization
Select whether the STOP/RESET
key on the keypad is enabled,
three option codes:
00
Enabled
01
Always disabled
02
Stop disabled (Reset enable)
Selects the rate of use (in %) of
the regenerative braking resistor
per 100 sec. intervals, range is
0.0 to 100%.
0%:
Selects when the fan is ON during
inverter operation, three options:
00
Fan is always ON
01
Fan is ON during run, OFF
during stop (5 minute delay
from ON to OFF)
02
Fan is temperature controlled
Two option codes:
00
Count
01
Clear
Description
Function disabled
Section 3-6
Run
Defaults
Mode
EU
Units
Edit
0.5
Hz
00
01
00
0.0
%
00
00
121