"C" Group: Intelligent Terminal Functions
Func.
Code
C028
[AM] terminal selection (Ana-
log voltage output 0...10V)
C030
Digital current monitor refer-
ence value
C047
Pulse train input/output scale
conversion
Func.
Code
C031
C032
C036
Func.
Code
C130
C131
C132
C133
C140
C141
136
"C" Function
Name
11 programmable functions:
00... Output frequency
01... Output current
02... Output torque
04... Output voltage
05... Input power
06... Electronic thermal load ratio
07... LAD frequency
10... Heat sink temperature
11... Output torque (with code)
13... General output
16... Option
Current with digital current moni-
tor output at 1,440Hz Range is
20%~200% of rated current
If EO terminal is configured as
pulse train input (C027=15), scale
conversion is set in C047. Pulse-
out = Pulse-in (C047) Set range
is 0.01 to 99.99
The output logic conversion is programmable for terminal [11], [12] and the
alarm relay terminal. The open-collector output terminal [11] and [12] defaults
to normally open (active low), but you can select normally closed (active high)
for the terminal in order to invert the sense of the logic. You can invert the log-
ical sense of the alarm relay output as well.
"C" Function
Name
Output [11] active state
Output [12] active state
Alarm relay active state
You can also adjust the output with ON/OFF delays.
"C" Function
Name
Output [11] on delay
Output [11] off delay
Output [12] on delay
Output [12] off delay
Relay output on delay
Relay output off delay
Note If you are using the output terminal OFF delay feature (any of C145, C149 > 0.0
sec.), the [RS] (reset) terminal affects the ON-to-OFF transition slightly. Nor-
mally (with using OFF delays), the [RS] input causes the motor output and the
logic outputs to turn OFF together, immediately. However, when any output
uses an OFF delay, then after the [RS] input turns ON, that output will remain
ON for an additional 1 sec. period (approximate) before turning OFF.
Description
Description
Select logic conversion, two
option codes:
00... normally open [NO]
01... normally closed [NC]
Description
Set range is 0.0 to 100.0 sec.
Set range is 0.0 to 100.0 sec.
Set range is 0.0 to 100.0 sec.
Section 3-7
Run
Defaults
Mode
EU
Units
Edit
07 [LAD-FQ]
Rated current
A
1.00
Run
Defaults
Mode
EU
Units
Edit
00
00
01
Run
Defaults
Mode
EU
Units
Edit
0.0
Sec.
0.0
Sec.
0.0
Sec.
0.0
Sec.
0.0
Sec.
0.0
Sec.

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents