Omron MX2 User Manual page 30

200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for MX2:
Table of Contents

Advertisement

MX2 Inverter Specifications
Item
Output signal Intelligent output terminal
48 functions assignable
Monitor output (analog)
Pulse train output
(0~10 Vdc, 32 kHz max.)
Alarm output contact
Alarm output contact
Other functions
Protective function
Operating
Temperature
environment
Humidity
Vibration *11
Location
Coating color
Options
8
General Specifications
RUN (run signal), FA1~FA5 (frequency arrival signal), OL,OL2 (overload
advance notice signal), OD (PID deviation error signal), AL (alarm signal),
OTQ (over/under torque threshold), UV (under-voltage), TRQ (torque limit
signal), RNT (run time expired), ONT (power ON time expired), THM (ther-
mal warning), BRK (brake release), BER (brake error), ZS (0Hz detection),
DSE (speed deviation excessive), POK (positioning completion), ODc
(analog voltage input disconnection), OIDc (analog current input discon-
nection), FBV (PID second stage output), NDc (network disconnect detec-
tion), LOG1~LOG3 (Logic output signals), WAC (capacitor life warning),
WAF (cooling fan warning), FR (starting contact), OHF (heat sink overheat
warning), LOC (Low load), MO1~MO3 (general outputs for EzSQ), IRDY
(inverter ready), FWR (forward operation), RVR (reverse operation), MJA
(major failure), WCO (window comparator O), WCOI (window comparator
OI), FREF (frequency command source), REF (run command source),
SETM (second motor in operation), EDM (STO (safe torque off) perfor-
mance monitor), OP (option control signal), NO (no function)
Output freq., output current, output torque, output voltage, input power,
thermal load ratio, LAD freq., heat sink temperature, general output (EzSQ)
[PWM output]
Output freq., output current, output torque, output voltage, input power,
thermal load ratio, LAD freq., heat sink temperature, general output (EzSQ)
[Pulse train output]
Output frequency, output current, pulse train input monitor
ON for inverter alarm (1c contacts, both normally open or closed available.)
ON for inverter alarm (1c contacts, both normally open or closed available.)
Free-V/f, manual/automatic torque boost, output voltage gain adjustment,
AVR function, reduced voltage start, motor data selection, auto-tuning,
motor stabilization control, reverse running protection, simple position con-
trol, simple torque control, torque limiting, automatic carrier frequency
reduction, energy saving operation, PID function, non-stop operation at
instantaneous power failure, brake control, DC injection braking, dynamic
braking (BRD), frequency upper and lower limiters, jump frequencies,
curve accel and decel (S, U, inversed U,EL-S), 16-stage speed profile, fine
adjustment of start frequency, accel and decel stop, process jogging, fre-
quency calculation, frequency addition, 2-stage accel/decel, stop mode
selection, start/end freq., analog input filter, window comparators, input ter-
minal response time, output signal delay/hold function, rotation direction
restriction, stop key selection, software lock, safe stop function, scaling
function, display restriction, password function, user parameter, initializa-
tion, initial display selection, cooling fan control, warning, trip retry, fre-
quency pull-in restart, frequency matching, overload restriction, over
current restriction, DC bus voltage AVR
Over-current, over-voltage, under-voltage, overload, brake resistor over-
load, CPU error, memory error, external trip, USP error, ground fault detec-
tion at power on, temperature error, internal communication error, driver
error, thermistor error, brake error, safe stop, overload at low speed, mod-
bus communication error, option error, encoder disconnection, speed
excessive, EzSQ command error, EzSQ nesting error, EzSQ execution
error, EzSQ user trip
Operating (ambient): -10 to 40°C (*10), / Storage: -20 to 65°C (*11)
20 to 90% humidity (non-condensing)
5.9m/s
(0.6G), 10 to 55 Hz
2
Altitude 1,000m or less, indoors (no corrosive gasses or dust)
Black
Remote operator unit, cables for the units, braking unit, braking resistor,
AC reactor, DC reactor, EMC filter, fieldbus
Section 1-2