Omron MX2 User Manual page 317

200 v class three-phase input 0.1 to 15 kw 200 v class single-phase input 0.1 to 2.2 kw 400 v class three-phase input 0.4 to 15 kw
Hide thumbs Also See for MX2:
Table of Contents

Advertisement

ModBus Data Listing
Register
Function name
No.
1375h to
(Reserved)
137Ah
137Bh
Brake Control Enable
137Ch
Brake Wait Time for Release
137Dh
Brake Wait Time for Acceleration b122
137Eh
Brake Wait Time for Stopping
137Fh
Brake Wait Time for Confirma-
tion
1380h
Brake Release Frequency
1381h
Brake Release Current
1382h
Braking frequency
1383h
(Reserved)
1384h
(Reserved)
1385h
Deceleration overvoltage sup-
pression enable
1386h
Decel. overvolt. suppress level
1387h
Decel. overvolt. suppress const.
1388h
Decel. overvolt. suppress propo-
tional gain
1389h
Decel. overvolt. suppress Inte-
gral time
138Ah to
(Reserved)
1393h
1394h
GS input mode
1395h to
(Reserved)
1399h
139Ah
Display ex.operator connected
139Bh to
(Reserved)
13A2h
13A3h
1st parameter of Dual Monitor
13A4h
2nd parameter of Dual Monitor
13A5h
(Reserved)
13A6h
Freq. set in monitoring
13A7h
Automatic return to the initial dis-
play
13A8h
Ex. operator com. loss action
13A9h
Data Read/Write select
13AAh to
(Reserved)
13ADh
13AEh
Inverter mode selection
13AFh to
(Reserved)
13B6h
13B7h
Initialization trigger
13B8h to
unused
1400h
Function
R/W
Monitoring and setting items
code
b120
R/W
0 (disabling), 1 (enabling)
b121
R/W
0 to 500
R/W
0 to 500
b123
R/W
0 to 500
b124
R/W
0 to 500
b125
R/W
0 to 40000
b126
R/W
0 to 2000
b127
R/W
0 to 40000
b130
R/W
0 (disabling), 1 (enabling), 2 (enabling
with acceleration)
b131
R/W
200 V class: 330 to 390 (V)
400 V class: 660 to 780 (V)
b132
R/W
10 to 3000
b133
R/W
0 to 500
b134
R/W
0 to 1500
b145
R/W
0 (non Trip) /1 (Trip)
b150
R/W
001 to 060
b160
R/W
001 to 030
b161
R/W
001 to 030
b163
R/W
0 (disabling), 1 (enabling),
b164
R/W
0 (disabling), 1 (enabling),
b165
R/W
0 (tripping), 1 (tripping after decelerating
and stopping the motor), 2 (ignoring
errors), 3 (stopping the motor after free-
running), 4 (decelerating and stopping
the motor)
b166
R/W
0 (Read/Write OK), 1 (Protected)
b171
R/W
0 (disabling), 1 (IM mode), 2 (High Freq.
mode), 3 (PM mode)
b180
R/W
0 (disabling), 1 (enabling),
Inaccessible
Section B-4
Data
resolution
0.01 [sec.]
0.01 [sec.]
0.01 [sec.]
0.01 [sec.]
0.01 [Hz]
0.1 [%]
0.01 [Hz]
1 [V]
0.01 [sec.]
0.01
0.1 [sec.]
-
295

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents