"A" Group: Standard Functions
Func.
Code
A044
A244
A045
A245
a046
a246
a047
a247
82
"A" Function
Name
V/f characteristic curve
V/f characteristic curve,
nd
2
motor
V/f gain
nd
V/f gain, 2
motor
Voltage compensation gain for
automatic torque boost
Voltage compensation gain for
automatic torque boost,
nd
2
motor
Slip compensation gain for
automatic torque boost
Slip compensation gain for
automatic torque boost,
nd
2
motor
Description
Four available V/f curves;
00... Constant torque
01... Reduced torque (1.7)
02... Free V/F
03... Sensorless vector (SLV)
Sets voltage gain of the inverter,
range is 20. to 100.%
Sets voltage compensation gain
under automatic torque boost,
range is 0. to 255.
Sets slip compensation gain
under automatic torque boost,
range is 0. to 255.
Section 3-5
Run
Defaults
Mode
EU
Units
Edit
00
00
100.
%
100.
%
100.
100.
100.
100.