Switch Lockout; Resetting The Switch; Figure 4-2 Change Password Screen - ZyXEL Communications ZyXEL Dimension ES-3024 User Manual

Zyxel ethernet switch user's guide
Hide thumbs Also See for ZyXEL Dimension ES-3024:
Table of Contents

Advertisement

Dimension ES-3024 Ethernet Switch

4.3 Switch Lockout

You are locked out from managing the switch if another administrator is currently logged in. You must wait until
he/she has logged out before you can log in.
Moreover, you could lock yourself (and all others) out from the switch by:
1. Deleting the management VLAN (default is VLAN 1).
2. Deleting all port-based VLANs with the CPU port as a member. The "CPU port" is the management port of
the switch.
3. Filtering all traffic to the CPU port.
4. Disabling all ports.
5. Assigning minimum bandwidth to the CPU port. If you limit bandwidth to the CPU port, you may find that the
switch performs sluggishly or not at all.
Be careful not to lock yourself and others out of the switch.

4.4 Resetting the Switch

If you lock yourself (and others) from the switch or forget the ES-3024 password, you will need to reload the
factory-default configuration file.
Uploading the factory-default configuration file replaces the current configuration file with the factory-default
configuration file. This means that you will lose all previous configurations and the speed of the console port will
be reset to the default of 9600bps with 8 data bit, no parity, one stop bit and flow control set to none. The
password will also be reset to "1234" and the IP address to 192.168.1.1.
To upload the configuration file, do the following:
Connect to the console port using a computer with terminal emulation software. See the Hardware
Step 1.
Connections chapter for details.
4-2

Figure 4-2 Change Password Screen

Introducing The Web Configurator

Advertisement

Table of Contents
loading

Table of Contents