Figure 14-2 Snmp Setup - ZyXEL Communications ZyXEL Dimension ES-3024 User Manual

Zyxel ethernet switch user's guide
Hide thumbs Also See for ZyXEL Dimension ES-3024:
Table of Contents

Advertisement

Dimension ES-3024 Ethernet Switch
GENERIC TRAP
2 (linkDown)
3 (linkUp)
4
(authenticationFailure)
6 (enterpriseSpecific) 1(TRAP_REBOOT)
14-4
Table 14-3 SNMP Traps
SPECIFIC TRAP
0
0
0
2
(TRAP_SYSTEMSHUTDO
WN)
3 (TRAP_OVERHEAT)
4
(TRAP_OVERHEATOVER)
5 (TRAP_ERRLOG)
6 (TRAP_FANRPMLOW)
7
(TRAP_FANRPMNORMAL)
8 (TRAP_VOLTAGELOW)
This trap is sent when the Ethernet is down.
This trap is sent when the Ethernet is up.
This trap is sent when an SNMP request comes from non-
authenticated hosts.
This trap is sent when the system is going to reboot. The trap
displays the reason for the reboot.
This trap is sent when the system is going to shut down. The
trap displays the reason for the shutdown.
This trap is sent when the temperature exceeds the threshold
of 65 degrees centigrade. For example, the following trap
shows that the current reading at Temp1 is 68 degrees
centigrade.
"Temp1 exceeds Limit (Limit = 65 degree C, Read = 68
degree C)"
This trap is sent when the temperature returns to normal.
For example, the following trap shows that the current reading
at Temp1 is 64 degrees centigrade.
"Temp1 back to Normal (Limit = 65 degree C, Read = 64
degree C)"
This trap is sent when an error log is recorded in the system.
The trap includes the content of the error log.
This trap is sent when the fan speed falls below 4000 RPM
("Limit", the minimum speed allowed). For example, the
following trap shows that the current reading at FAN 1 is 3800
RPM.
"FAN1 exceeds Limit (Limit = 4000 RPM, Read = 3800 RPM)"
This trap is sent when the fan speed returns to normal.
For example, the following trap shows that the current reading
at FAN 1 is 5500 RPM.
"FAN1 back to Normal (Limit = 4000 RPM, Read = 5500
RPM)"
This trap is sent when the voltage falls out of the tolerance
range.
For example, the following trap shows that the current reading
at the 3.3V sensor is 3.00V, the upper voltage limit is 3.36V
and the lower voltage limit is 3.10V.
"Power 3.3V exceeds Limit (Up Limit = 3.36V, Down Limit =
3.10V, Read = 3.00V)"
DESCRIPTION
SNMP Setup