2. Verify that the fabric planes come online correctly by issuing the show chassis fabric summary command:
user@switch> show chassis fabric summary
Plane
State
Uptime
0
Online
2 days, 19 hours, 10 minutes, 9 seconds
1
Online
2 days, 19 hours, 10 minutes, 9 seconds
...
3. Verify that the backup Routing Engine is back online by issuing the show chassis routing-engine 1
command:
user@switch> show chassis routing-engine 1
Routing Engine Status:
Slot 1:
Current State
...
4. Verify that the EX9200-SF3s appear in output from the show chassis hardware command:
user@switch> show chassis hardware
Hardware inventory:
Item
Version Part number Serial number
Chassis
Midplane
REV 01
FPM Board
REV 04
PEM 0
Rev 10
PEM 1
Rev 10
Routing Engine 0 REV 02
Routing Engine 1 REV 02
CB 0
REV 08
CB 1
REV 10
...

Removing an SF Module from an EX9200 Switch

Before you begin to remove an SF module:
• Ensure you understand how to prevent electrostatic discharge (ESD) damage. See
Electrostatic Discharge Damage
Backup
JN1221A03RFC
750-053633
ACRA1451
760-021392
ABCB4822
740-029970
QCS1251U020
740-029970
QCS1251U028
740-049603
9009153805
740-049603
9009153993
750-048307
CABC6474
750-048307
CABH8948
.
Description
EX9204
EX9204-BP
Front Panel Display
PS 1.4-2.52kW; 90-264V AC in
PS 1.4-2.52kW; 90-264V AC in
RE-S-EX9200-1800X4
RE-S-EX9200-1800X4
EX9200-SF3
EX9200-SF3
Prevention of
236

Advertisement

Table of Contents
loading

Table of Contents