• Connections between connectors;
• When routing the cables, ensure that all cables are routed appropriately through the cable guides.
This configuration contains the following storage controller combinations:
•
"16i + 16i + 16i RAID/HBA adapter" on page 410
•
"8i + 16i + 32i RAID/HBA adapter" on page 412
•
"32i + 32i RAID adapter" on page 414
16i + 16i + 16i RAID/HBA adapter
NVMe cable routing
From
BP1: NVMe 0-1
1
BP1: NVMe 2-3
2
BP1: NVMe 4-5
3
BP1: NVMe 6-7
4
BP2: NVMe 0-1
5
BP2: NVMe 2-3
6
BP2: NVMe 4-5
7
BP2: NVMe 6-7
8
BP3: NVMe 0-1
9
BP3: NVMe 2-3
10
ThinkSystem SR860 V3 User Guide
410
↔
↔
↔
,
,
, ...
1
1
2
2
3
3
n
To
System board: NVMe 10
System board: NVMe 9
System board: NVMe 1
System board: NVMe 2
System board: NVMe 3
System board: NVMe 4
System board: NVMe 5
System board: NVMe 6
System board: NVMe 7
System board: NVMe 8
↔
n
Cable
SlimSAS x8 to SlimSAS x8 (440 mm)
SlimSAS x8 to SlimSAS x8 (440 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)
SlimSAS x8 to SlimSAS x8 (190 mm)