• If you intend to install memory modules in the server, you must first remove the air baffle from the server.
• For proper cooling and airflow, reinstall the front and rear air baffles before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Procedure
Step 1.
Align the rear air baffle tabs with the rear air baffle slots on both sides of the chassis; then, lower the
rear air baffle into the server.
Note: Close the retaining clip on each end of the memory module connector before installing the
front air baffle for proper cooling.
Figure 54. Installing rear air baffle for 3U standard PHM
.
Chapter 5
Hardware replacement procedures
99