Lenovo ThinkSystem SR860 V3 User Manual page 145

Hide thumbs Also See for ThinkSystem SR860 V3:
Table of Contents

Advertisement

• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top covers,
or remove the server from the rack. See
Procedure
Step 1.
Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server; then, take the new part out of the package and place it on a static-protective
surface.
Step 2.
Install the flash power module.
Figure 86. Flash power module installation
a.
Note the orientation of the flash power module; then, gently insert the flash power module
into the retaining clip at one side as shown.
b.
Press the flash power module down on the other side until it snaps into place.
Step 3.
Connect the cable of the RAID flash power module to the extension cable.
Figure 87. Connecting cable to flash power module
58.
"Remove the server from rails" on page
58.
.
Chapter 5
Hardware replacement procedures
135

Advertisement

Table of Contents
loading

This manual is also suitable for:

7d937d947d95

Table of Contents