Lenovo ThinkSystem SR860 V3 User Manual page 101

Hide thumbs Also See for ThinkSystem SR860 V3:
Table of Contents

Advertisement

• Read
"Installation Guidelines" on page 43
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top covers,
or remove the server from the rack. See
• If you intend to install memory modules in the server, you must first remove the air baffle from the server.
• For proper cooling and airflow, reinstall the front and rear air baffles before you turn on the server.
Operating the server with the air baffle removed might damage server components.
Procedure
Step 1.
Align the front air baffle tabs with the front air baffle slots on both sides of the chassis; then, lower
the front air baffle into the server.
Note: Close the retaining clip on each end of the memory module connector before installing the
front air baffle for proper cooling.
Figure 43. Installing front air baffle
Step 2.
Slightly press the front air baffle down until it is securely seated.
Step 3.
Route the cables through the front air baffle.
and
"Safety inspection checklist" on page 44
58.
"Remove the server from rails" on page
58.
.
Chapter 5
Hardware replacement procedures
to ensure that you
91