• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top covers,
or remove the server from the rack. See
Procedure
Step 1.
Align the fan module over the fan slot in the fan cage assembly, and insert the fan module into the
fan cage assembly until it clicks into place.
Figure 83. Installing a fan module
Notes:
• Make sure to replace a defective fan module with another unit of the exact same type.
• Do not mix single and dual rotor fan modules in the same unit of server.
Attention: With power on, complete the replacement within 30 seconds to ensure proper
operation.
After you finish
1. Reinstall the front top cover. See
2. Complete the parts replacement. See