• Read
"Installation Guidelines" on page 43
work safely.
• Power off the server and peripheral devices and disconnect the power cords and all external cables. See
"Power off the server" on page
• Prevent exposure to static electricity, which might lead to system halt and loss of data, by keeping static-
sensitive components in their static-protective packages until installation, and handling these devices with
an electrostatic-discharge wrist strap or other grounding system.
• If the server is installed in a rack, slide the server out on its rack slide rails to gain access to the top covers,
or remove the server from the rack. See
Firmware and driver download: You might need to update the firmware or driver after replacing a
component.
• Go to
https://datacentersupport.lenovo.com/products/servers/thinksystem/sr860v3/7d93/downloads/driver-
to see the latest firmware and driver updates for your server.
list/
• Go to
"Update the firmware" on page 435
Procedure
Step 1.
Touch the static-protective package that contains the new part to any unpainted surface on the
outside of the server; then, take the new part out of the package and place it on a static-protective
surface.
Step 2.
Install the firmware and RoT security module to the server.
Figure 210. Firmware and RoT security module installation
a.
Lower the firmware and RoT security module onto the system I/O board and ensure that the
connector on the module is correctly inserted into the slot on the system I/O board.
b.
Tighten the two screws to secure the firmware and RoT security module in place.
After you finish
ThinkSystem SR860 V3 User Guide
260
and
"Safety inspection checklist" on page 44
58.
"Remove the server from rails" on page
for more information on firmware updating tools.
to ensure that you
58.