Telegram Types - Siemens SINAMICS G120 Function Manual

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

3.3.2

Telegram types

Two telegrams are available for the data exchange via PROFIsafe between the inverter and
the higher-level controller:
Table 3- 5
Telegram types
Telegram type
Process data (PZD) - control
and status words
PZD1
Telegram 30
STW1
PZD 1/1
ZSW1
Telegram 900
STW1
PZD 2/2
ZSW1
STW: Control word; ZSW: Status word
The higher-level controller triggers the safety functions in the inverter via the control word.
The inverter uses the status word to report the status of the safety functions to the controller.
The section Selecting the commissioning method (Page 108) contains information to help
you decide whether you must operate your inverter with "Basic Safety" or "Extended Safety".
Safety Integrated Function Manual, SINAMICS G120 and G120C
Function Manual, 01/2011, FW 4.4, A5E03052391B AB
Optional with:
PZD2
---
Basic Safety
and
Extended Safety
---
STW5
Extended Safety
ZSW5
3.3 Activation via PROFIsafe
Available for SINAMICS
G120 with the following
Control Units
CU240E-2
CU240E-2 DP
CU240E-2 F
CU240E-2 DP-F
CU240E-2 DP-F
Interfaces
Available with
SINAMICS G120C
G120C DP
---
95

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sinamics g120c

Table of Contents