Figure 2-14
PROFIsafe status word 1
Bit 10
0
0
1
1
Safety Integrated Function Manual, SINAMICS G120 and G120C
Function Manual, 01/2011, FW 4.4, A5E03052391B AB
Switching between different monitoring thresholds
Bit 9
0
1
0
1
2.5 Safely Limited Speed, SLS
Active SLS level
Level 1
p9531[0]
Level 2
p9531[1]
Level 3
p9531[2]
Level 4
p9531[3]
Description