Reduced Acceptance Test - Siemens SINAMICS G120 Function Manual

Hide thumbs Also See for SINAMICS G120:
Table of Contents

Advertisement

Commissioning
4.9 Acceptance test - Completion of commissioning
4.9.3

Reduced acceptance test

A complete acceptance test is only necessary following first commissioning. An acceptance
test with a reduced scope is sufficient for expansions of safety functions.
The reduced acceptance tests must be carried out separately for each individual drive, as far
as the machine allows.
Table 4- 5
Reduced acceptance test for function extensions
Measure
Replacing the Control Unit
(SINAMICS G120) or the inverter.
Replacing the Power Module.
Replacing the motor
Replacing the gear unit
Replacing the safety-related
peripherals (e.g. Emergency Stop
switch).
Inverter firmware update.
Changing a single limit (e.g. SLS
level).
Functional expansion of the
machine (additional drive).
Functional expansion of a drive
(e.g. additional SLS level).
Transfer of inverter parameters to
other identical machines by means
of standard commissioning.
166
Documentation
Supplement:
Inverter data
Supplement:
Hardware version in the
inverter data
No
No
No
Supplement:
Firmware version in the
inverter data
Supplement:
Function table
Limit values
Supplement:
Machine overview
Inverter data
Function table
Limit values
Supplement:
Function table
Limit values
Supplement to the machine
description (checking of the
firmware versions).
Acceptance test
Function test
Yes
Yes
Yes
Restriction to safety
function SDI.
Yes
Yes
Limitation to replaced
components.
Yes
Yes
Restriction to changed
limit value.
Yes
Restriction to additional
functions.
Yes
Restriction to additional
functions.
Yes
Safety Integrated Function Manual, SINAMICS G120 and G120C
Function Manual, 01/2011, FW 4.4, A5E03052391B AB
Conclusion of the report
Supplement:
New checksums and
countersignature
No
No
No
No
Supplement:
New checksums and
countersignature.
Supplement:
New checksums and
countersignature.
Supplement:
New checksums and
countersignature.
Supplement.
New checksums and
countersignature.
No, if data are identical
(checking of checksums).