Error Codes
Code
Meaning
The control channel started
0-87
after an unsuccessful
primary channel.
The line was disconnected
because PPR was
0-88
transmitted/received 9
(default) times within the
same ECM frame.
Only one V.21 connection
2-11
flag was received
2-12
Modem clock irregularity
2-13
Modem initialization error
JBIG compression or
2-23
reconstruction error
2-24
JBIG ASIC error
JBIG data reconstruction
2-25
error (BIH error)
JBIG data reconstruction
2-26
error (Float marker error)
JBIG data reconstruction
2-27
error (End marker error)
JBIG data reconstruction
2-28
error (Timeout)
JBIG trailing edge maker
2-29
error
D545
Suggested Cause/Action
The receiving terminal restarted the control
channel because data reception in the primary
channel was not successful.
This does not result in an error
communication.
Try using a lower data rate at the start.
Try adjusting the cable equalizer setting.
Replace the FCU.
Replace the FCU.
Turn off the machine, then turn it back on.
Update the modem ROM.
Replace the FCU.
Turn off the machine, then turn it back on.
Turn off the machine, then turn it back on.
JBIG data error
Check the sender's JBIG function.
Update the MBU ROM.
FCU defective
Check the destination device.
28
SM