with the router can damage the power terminal. These power cords are specifically designed to
be used only with the specified ACX500 outdoor routers.
WARNING: You must ground the router before connecting the power cables.
NOTE: For disconnecting power to the router, first remove or switch off the power to the power
cord by opening the circuit breaker or suitable service disconnect at the AC disconnect box or
power distribution unit (PDU). Then rotate the power cord connector ring to disconnect the
power cord from the router connector. Doing this ensures that the power cord is safe to handle.
NOTE: The information provided in this topic is applicable for both the ACX500 outdoor router
variants—ACX500 outdoor router and ACX500 outdoor router with PoE.
To connect AC power to the router:
1.
Attach an ESD grounding strap to your bare wrist, and connect the other end of the strap to an ESD
grounding point.
2.
Locate the power cord that is compatible with the ACX500 outdoor router.
Power cords for the ACX500 outdoor routers are not shipped with the router. The power cords are
specifically designed to be used only with the specified ACX500 outdoor routers. The unique
design of these power cords help to protect the power terminal from the external environmental
factors, such as water and dust.
166