2
1. Inlet hose
2. Filter indicator
3. Air cleaner
4. Inlet
5. Dust reservoir
UDRF01.04GB
1 Engine – 1.6 Air intake and exhaust outlet
1.6
1.6.1
Air filter, changing
1 Machine in service position, see section B Safety.
3
4
5
2 Clean the outside of the air filter housing.
3 Remove the cap from the air filter housing.
4 Remove the filter cartridge.
5 Clean the particle outlet.
6 Check the safety cartridge, change as needed. (The safety car-
7 Fit a new filter cartridge and fit the cap.
8 Reset the indicator.
Maintenance manual DRF 400–450
https://www.forkliftpdfmanuals.com/
Air intake and exhaust
outlet
Air cleaning system
tridge should be changed every other time the filter cartridge is
changed).
NOTE