Synchronous Lift - Kalmar DRF420-60S5 Maintenance Manual

Table of Contents

Advertisement

page
Condition
Control switch
1
+
1.
Control lever (S815)
2.
Control unit cab (D790-1)
3.
Sensor boom angle (B771)
7 Load handling – 7.10.4 Synchronous lift
7.10.4
Synchronous lift, function description
Synchronized lift means that lift and extension are activated at the
same time so that the lift is completely vertical. Synchronized lift is
activated by pressing in the pistol trigger on the control lever at the
same time as lift is activated.
Synchronized lift is controlled by the control system with signals
from Sensor boom angle and Sensor boom length.
NOTE
The synchronized lift uses preset variables for the speed. The
hydraulic oil pumps must be adjusted correctly for the function
to work well.
For details on lift and extension, see Lift and lower, function descrip-
tion page 4 and Extension, function description page 10.
Reference value
Not activated
D
2
D790-1
D795
D797-R
D797-F
5
D
m
4
3
Maintenance manual DRF 400–450
https://www.forkliftpdfmanuals.com/

Synchronous lift

4.
Sensor boom length (B777)
5.
Control unit frame rear (D797-R)
67
UDRF01.04GB

Advertisement

Table of Contents
loading

Table of Contents