11 Common electrics – 11.5 Distribution of electricity
11.5
Distribution of electricity, description
This section describes the distribution of electric power and commu-
nication between the control units. The distribution of electric pow-
er describes the basics of the electrical system and the network of
control units.
11.5.1
Start-up of electrical system, description
When the machine isn't in use, the electrical system is in a power-
less mode, that is, neither power electronics nor controls units are
supplied with voltage. When the machine is started, voltage feed is
activated and the redundant CAN bus is initiated. Start-up is handled
by control unit cab (D790-1).
The first pre-requisite for the machine to be able to perform any ac-
tion is to first establish the redundant voltage feed for control units
and then establish CAN-bus communication to administer control
signals for functions.
Control units establish communication when:
Start-up
The following takes place at start-up:
1.
2.
D791-2
(D791-3 / D791-4)
D791
D795
D797-O
D797-F
Maintenance manual DRF 400–450
https://www.forkliftpdfmanuals.com/

Distribution of electricity

Voltage feed

Operator's door is opened
Interior lighting is lit
Flashing hazard lights are activated
Start key in position I
Start-up signal to Control unit cab (D790-1).
Control unit cab (D790-1) initiates connection of redundant volt-
age feed. See Redundant voltage feed of control units, descrip-
tion page 12.