8 Control system – 8.2 Monitoring
8.2
Monitoring functions, general
The machine is equipped with a number of control functions to in-
crease safety during load handling:

Overloading system

By-passing
Load-centre limitation
Height limitation
Speed limitation
Service indicator
8.2.1
Overloading system, general
The machine is equipped with a warning system, LLMC (Longitudinal
Load Moment Control). Warning systems shall ALWAYS be function-
al! The system shall be used for stationary load handling, so that the
machine's forward stability is not jeopardized.
The following happens when the machine approaches the stability
limit:
the buzzer in the cab sounds (indication to operator)
warning figure is shown in the display (indication to operator)
boom movement is interrupted
In this position the boom, and thus the load, can only be retract-
ed until the buzzer stops sounding and the display figure disap-
pears.
LLMC is not intended to control sideways stability or stability when
operating. Also, it does not take angled ground conditions into ac-
count.
NOTE
Retract the boom before it is lowered! Applies to all load han-
dling!
The overloading system is activated when the operator exceeds the
machine's load handling capacity. When the overloading system is
active all hydraulics are blocked, e.g., lift. With Switch by-pass, cer-
tain parts of the overloading system can be by-passed. This makes it
possible to lower and retract the boom to avoid dangers.
There are three versions of overloading system:
Mechanical overloading system, function description page 8
Mechanical overloading system with analogue position sensors,
function description page 9
Electrical overloading system, function description page 10