8 Control system – 8.2.4 Height limitation
8.2.4
Height limitation, description
Height limitation is a part of the control system and prevents the ma-
chine from lifting higher than a pre-set height without the operator
being informed.
Height limitation is controlled by the control system with signals
from Sensor boom angle and Sensor boom length. When boom angle
and extension indicate that permitted height is reached, lift and ex-
tension are blocked and display information height limitation is acti-
vated.
For details about lift, lower and extension, see section 7 Load han-
dling.
8.2.5
Speed limitation, description
Speed limitation prevents the machine's speed from exceeding pre-
set value by limiting gear position and engine rpm.
8.2.6
Service indicator, resetting
1 Machine in service position, see section B Safety.
2 Navigate first to the service menu and press Enter.
3 Enter code for resetting service indicator.
NOTE
4 Reset the service indication by pressing Enter. NEXT SERVICE is
XXXXh
XXXXh
XXXXh
Maintenance manual DRF 400–450
https://www.forkliftpdfmanuals.com/

Height limitation

Speed limitation

Service indicator

The code is obtained via Kalmar Industries Support.
The code determines which service menu shall be activat-
ed (Service, Diagnostic test, Initiation or Calibration).
changed to given interval.
To change length of the service interval, set the desired interval
with the plus and minus key.