Enabling The Boot Watchdog - Fujitsu PRIMERGY TX2550 M5 Upgrade And Maintenance Manual

Hide thumbs Also See for PRIMERGY TX2550 M5:
Table of Contents

Advertisement

▶ Enter the commands below, followed by [ENTER]:
1. /etc/init.d/srvmagt stop
/etc/init.d/srvmagt_scs stop
/etc/init.d/eecd stop
/etc/init.d/eecd_mods_src stop
2. cd /etc/srvmagt
3. rm -f cehist.bin
4. /etc/init.d/eecd_mods_src start
/etc/init.d/eecd start
/etc/init.d/srvmagt start
/etc/init.d/srvmagt_scs start
▶ Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using Infrastructure Manager
The status of server (node) which failed CPU is installed becomes error.
When replacing the CPU, the status will be updated after getting information
manually or automatically updated daily.
Proceed as follows to get node information with Infrastructure Manager:
▶ Start up the GUI of the Infrastructure Manager and login.
▶ Display the node list from menu (manage > node).
▶ Select the target node and display the detail screen.
▶ Execute getting node information from action menu.
5.3.8

Enabling the boot watchdog

If the boot watchdog has been disabled for firmware upgrade purposes (see
"Disabling the boot watchdog" on page
complete the maintenance task.
TX2550 M5
108), it has to be re-enabled to
Upgrade and Maintenance Manual
Basic software procedures
123