Fujitsu PRIMERGY TX2550 M5 Upgrade And Maintenance Manual page 439

Hide thumbs Also See for PRIMERGY TX2550 M5:
Table of Contents

Advertisement

1 SATA cable C3 from the accessible drive
"SATA ODD" on system board
2 Power adapter cable C25 to the accessible drive
3 Power adapter cable C25 to a free connector of the power cable
(Figure
286, 3)
4 Power cable C8 to connector "ODD" on system board
▶ Run the SATA cable C3 through the crossbar
▶ Run the ODD cables through the cable clamp
▶ Run the ODD cables through the cable guide
For the cable plan see
Connecting cables to the LTO drive or the RDX drive
For connecting an RDX drive or an LTO drive, see the cable plan in
"Appendix B" on page
Connecting cables to the LTO drive
▶ Connect the PWR/SAS cable to the LTO drive.
▶ Connect the SAS connector of the PWR/SAS cable to the "MLC1" connector
of the PSAS controller.
▶ Connect the PWR connector of the PWR/SAS cable to the connector "X17"
of the corresponding SAS backplane.
Connecting cables to the RDX drive
▶ Connect the power adapter cable C24 to the RDX drive.
▶ Connect the power adapter cable C24 to a free connector of the power
cable C8.
▶ Connect the power cable C8 to the connector PWR ODD on the system
board.
▶ Connect the USB cable C20 from the RDX drive to the connector "USB3.0
INT1" on the system board.
TX2550 M5
"Appendix B" on page
589.
Upgrade and Maintenance Manual
Accessible drives
(Figure
286, 1) to connector
(Figure
286, 2)
(Figure
(Figure
287, 3).
Figure
287, 4).
(Figure
287, 5).
589.
287, 2)
439