Basic software procedures
Using ServerView Maintenance Tools (Windows only)
▶ Launch the ServerView Maintenance Tools:
Start > Apps > Fujitsu > Maintenance Tools
▶ Choose the CPU status tab.
▶ Select the CPU which shows the pre-failure status.
▶ Click on Reset Status.
▶ Ensure that all pre-fail/fail status issues have been resolved in ServerView
Operations Manager.
Using the command line (Linux only)
Proceed as follows to reset the error counter of a specific CPU:
▶ Log in as root.
▶ Enter the command below, followed by [ENTER]:
<CPU#> parameters are "0" for CPU 1 and "1" for CPU 2.
For rack and floorstand servers (RX and TX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#>
For blade and scale-out servers (BX and CX server series):
/usr/sbin/eecdcp -c oc=0609 oi=<CPU#> cab=<cabinet nr>
To identify the cabinet number, enter the following command:
/usr/sbin/eecdcp -c oc=E204
If the error status cannot be reset with the method above, please use the
following procedure for resetting the error counter of all CPUs:
▶ Log in as root.
122
Upgrade and Maintenance Manual
TX2550 M5