DISPENSING MATERIAL
The operator may select the Continuous (CONT ) or TIMED Mode of operation.
The CONT Mode allows the operator to dispense the material for as long as the foot pedal remains
depressed. The TIMED/CONT Switch must be placed in the CONT position for use in this mode. This
mode is recommended for use when dispensing a continuous bead of material.
The TIMED Mode allows the operator to select a dispense time of 0.1 to 10 seconds as determined by the
PASTE (DISP) Timer Control. The TIMED/CONT Switch must be placed in the TIMED position for use in
this mode. Use of this mode is recommended for all dot dispensing applications.
Follow the procedure below to obtain proper results.
1. Insure that the proper material and tip have been
installed.
2. Set the TIMED/CONT Switch for the mode of operation
desired. Set the switch to CONT for continuous
operation or TIMED for timed operation.
3. If in the TIMED Mode, set the PASTE (DISP) Timer
Control to the desired dispense time period.
84
Figure 105. Timed/Cont Switch
Figure 106. Paste Disp Timer