UPPER TEMPERATURE LIMIT
14. The Digital Readout now displays "H-X" (X = 1-9).
This is the stored value of the upper temperature limit
in increments of 100°F.
15. Press Scroll Keys as necessary to increase (Scroll
Up Key) or decrease (Scroll Down Key) the upper
temperature limit.
16. Press and release the TIP SET Key. The Digital
Readout will now display "CAL". The next Active
Channel now becomes the Current Channel.
Perform steps 11 through 16 to set upper and lower
temperature limits for the other channels (CH 1, CH
2, CH 3, AUX 1, AUX 2 and AUX 3). After all
channels have been calibrated, you may exit the
Calibration (CAL) Mode by pressing and releasing
the TIP OFFSET Key.
Figure 87. Digital Readout "H - X"
Figure 88. Change Upper Temp. Limit
Figure 89. Press Tip Set Key