°F/°C READOUT DEFAULT
5. Press and release the TIP SET Key. The Digital
Readout will display "S - X" (X = "-" or 1-9). Either the
°F or °C LED will be on. This is the default temperature
scale of the Digital Readout (e.g., if the °C LED is on,
the Digital Readout will display Tip Temperatures and
Tip Offset values in °C).
6. Press and release the °F/°C Key to change the default.
Each subsequent press and release of the key will
change the default.
AUTOMATIC TEMPERATURE SETBACK
7. As received from the factory, "S - -" will be displayed
indicating that the Automatic Temperature Setback is
turned off. A "1" thru "9" appearing on the right side of
the Digital Readout indicates time to Automatic
Setback in increments of 10 minutes. For example, "S-
3" would indicate that any Active Channel will set back
its handpieces' Set Tip Temperature to 180°C (350°F)
after 30 minutes of handpiece inactivity (non-use). To
change the time period or turn the Automatic
Temperature Setback feature off or on, use the Scroll
Keys. Press the Scroll Up Key to increase the time
period and/or enable the feature. Press the Scroll Down
Key to decrease the time period or disable the feature.
64
Figure 80. Digital Readout "S - X"
Figure 81. Change Temperature Default
Figure 82. Adjust Setback Time