Pace PRC 2000 Operation & Maintenance Manual page 107

Hide thumbs Also See for PRC 2000:
Table of Contents

Advertisement

S Y M P T O M
Foot Pedal does not activate
vacuum or air pressure for
Thermal Management
Keys on Thermal
Management Center don't
function properly.
Cannot adjust Offset or Set
Tip Temperature on Thermal
Management Center. Digital
Readout displays "P--".
Digital Readout on Thermal
Management Center is grossly
inaccurate.
Table 7. Corrective Maintenance, Power Source Cont'd
PROBABLE
Foot Pedal connected to
incorrect receptacle for
Center.
Thermal Mgt. Center motor
pump activation.
Defective motor pump.
Microprocessor pcb defect.
Key caps binding.
Display pcb misaligned or
defective.
Microprocessor pcb
defective.
System is requesting
Password entry.
Operator forgot Password.
System out of calibration.
Shorted handpiece or
accessory connected to
AUX or Power Receptacle.
Defective Microprocessor
pcb.
CAUSE
SOLUTION
Connect Foot Pedal to any spare AUX
Power Receptacle on Thermal
Management Center.
Contact PACE Service Department.
Contact PACE Service Department.
Clean and/or adjust Key caps.
Contact PACE Service Department.
Contact PACE Service Department.
Enter Password.
Clear Password. See "Clearing a
Password" instructions.
Wait 4 minutes for system to perform
automatic internal recalibration.
Disconnect handpieces and
accessories. Repair defective
handpiece or accessory.
Contact PACE Service Department.
107