Replacing the Power Supply Front Fan — Quantum Ultra 610 Only
The largest (front) fan cools the power supplies on the Quantum Ultra 610 (the fans of
the Quantum Ultra II 610 power supplies are within the power supply casings and are not
user-replaceable).
If a Quantum Ultra 610 power supply fan fails, you can order a new one from
www.extron.com
that is, it can be replaced while the Quantum Ultra 610 is operating, without the need to
power down the unit.
ATTENTION:
1.
Quantum Ultra Series Videowall Processing Systems • Maintenance — Quantum Ultra 610 Only
Remove the front and rear panels from the replacement power supply by
unfastening the three screws on the front and back panels. (These panels and screws
are no longer needed.)
Attach the front plate that was removed from the failed redundant power supply in
step 2 to the three holes on the back panel of the replacement power supply. Use the
three round-headed screws that also were removed in step 2.
Attach the metal strip from the failed power supply to the three holes on the front of
the replacement power supply, using the three flat-headed screws removed in step 3.
Perform
steps 6 through 10
beginning on page 92.
and replace it as described in this section. This fan is hot-swappable,
When a fan fails, replace it immediately. Do not run the unit for a long period
without a fan.
Lorsqu'un ventilateur cesse de fonctionner, remplacez-le immédiatement. Ne
prolongez Pas le fonctionnement de l'unité sans ventilateur.
Use a screwdriver to loosen the two thumbscrews on the cover panel and remove the
panel (see figure 96).
Loosen the thumbscrews.
Take off the panel.
Figure 96.
Removing the Cover Panel