9.
Use a screwdriver to tighten the two thumbscrews on the power supply as follows:
a.
Grasp the screw firmly and press it inward.
b.
Continue to press inward as you turn the screw to the right, until it is securely in
place.
10.
Reattach the protective cover panel (Quantum Ultra 610 only, see figure 89,
page 96).

Replacing the Redundant Power Supply

Replacing the redundant (bottom) power supply requires some additional steps to be
performed within the procedure described in the previous section. The primary and
redundant power supplies are essentially the same unit, but they are configured slightly
differently in order to fit into their slots in the chassis.
The replacement power supply kit is shipped with the power supply configured to replace
the top (primary) PSU. If the lower (redundant) power supply fails instead, you must
replace the front and back metal plates of the new PSU with those of the failed redundant
power supply.
1.
Perform
starting on page 96, to remove the redundant power supply from the chassis.
2.
Remove the front plate (containing the latch, handle, and thumbscrews) from the
failed redundant power supply by unfastening the three round-headed Philips screws
at the top of the plate (see figure 94). Retain the front plate and screws to attach to
the replacement power supply in step 5.
Figure 94.
3.
Remove the metal strip from the back of the failed redundant power supply by
unfastening the three flat-headed screws (see figure 95). Retain the back plate and
screws to reattach the strip in step 6.
Figure 95.
Quantum Ultra Series Videowall Processing Systems • Maintenance — Quantum Ultra 610 Only
steps 1 through 5
of the primary power supply replacement procedure,
Remove three screws.
Removing the Plate from the Failed Redundant Power Supply
Front Panel
Remove three screws.
Removing the Metal Strip from the Failed Power Supply Back
Panel
on