Command And Response Table For Sis Commands - Extron electronics Quantum Ultra Series User Manual

Videowall processing systems
Hide thumbs Also See for Quantum Ultra Series:
Table of Contents

Advertisement

Command and Response Table for SIS Commands

Command
Input Switching and Configuration
Input Selection
Select input
View current input
KEY:
X!
Input number: 0 through 9999 (assigned by the VCS program). Response is four digits with leading zeros.
=
0 = Window without source.
1-999 = Physical video connections on all chassis in the system.
1000-9999 = VNC, image, text, and clock sources defined in the system
X#
Canvas number: 1 through 10. Response is two digits with leading zero.
=
0 = All canvases (for window mute and preset recall only)
X%
Window number: 1 through 999. Response is three digits with leading zeros.
=
0 = All windows (for window mute only)
Input Name
To clear an input name, enter a single space for
NOTE:
Write name
NOTE:
Each input name must be unique. If you enter a name that already exists, the system returns an
response.
View name
Input Resolution Support
NOTES:
If 300 MHz support is enabled for an input, the adjacent input is disabled. For example, if an HDMI 2.4 input is set to
300 MHz, the HDMI 2.3 input is disabled.
These commands are supported for HDMI n.2 and n.4 inputs only.
Set resolution support
for an input
View supported
resolution
KEY:
X!
=
Input number: 0 through 9999 (assigned by the VCS program). Response is four digits with leading zeros.
0 = Window without source.
1-999 = Physical video connections on all chassis in the system.
1000-9999 = VNC, image, text, and clock sources defined in the system
X1$
Name or text label (for inputs) — Up to 32 characters. Invalid characters: \ / : * ? , > |.
=
X8$ =
Input resolution support: 0 = Up to 165 MHz, 1 = Up to 300 MHz
Quantum Ultra Series Videowall Processing Systems • Remote Configuration and Control
ASCII Command
Response
(Host to Processor)
(Processor to Host)
X#
X%
X!
*
*
!
Grp
X#
X%
X! ]
*
!
In verbose modes 2 and 3:
Grp
X1$
E X!
X1$
}
Nmi X! , X1$ ]
,
NI
E X!
}
X1$ ]
NI
In verbose modes 2 and 3:
Nmi
E X!
X8$
}
*
ITYP
Ityp
E X!
}
X8$ ]
ITYP
X#
X%
X! ]
• Win
• In
Select input
on canvas
View currently selected input
X!
X#
X#
X%
X! ]
• Win
• In
. This resets the input name to the default.
Set name
X!
X1$ ]
,
X!
X8$ ]
*
Set input
X8$
Set input
165 MHz resolution.
Additional Description
X!
X%
for window
X#
.
X%
in window
on canvas
.
X1$
X!
for input
.
E13
error
X!
to support up to
resolution.
X!
to support up to
68

Advertisement

Table of Contents
loading

Table of Contents