QUANTUM ULTRA 305
POWER
SYSTEM
A A A
DISCONNECT
POWER
CORD BEFORE
SERVICING
C C C
D D D
PRIMARY AC power connector
A
POWER switch
C
HDMI OUT system output port
D
USB system connectors
E
Figure 8.
PRIMARY POWER connector — Connect AC power to this IEC connector for the
A
primary power supply.
REDUNDANT POWER connector (Quantum Ultra and Ultra II 610 only) —
B
(Optional) Connect a second AC power source to this IEC connector for the
secondary power supply to provide uninterrupted operation in the event of failure of
the primary supply.
NOTES:
For Quantum Ultra II 610 only:
POWER switch — Press this momentary rocker switch to power the unit (both
C
power supplies) off and on.
Quantum Ultra Series Videowall Processing Systems • Installation and Configuration
INPUTS
INPUTS
OUTPUTS
OUTPUTS
REMOTE
LAN
A
B
RS-232
OUTPUTS
CONFIG
DTP POWER
12V
4A MAX
Tx Rx G
E E E
F F F
G G G
H H H
Quantum Ultra and Ultra II 305, Quantum Ultra Connect 128, and
Quantum Ultra Connect 84 Rear Panel
The Quantum Ultra II 610 model has IEC C20
power connectors (shown at right), while the
Quantum Ultra and Quantum Ultra II 305 models
have standard US IEC connectors. The
Quantum Ultra II 610 requires an IEC C19 power cord
to connect AC power.
Temperature controlled fans run at 100% as a failsafe
if only one power supply is operational.
North America — Connect the equipment to a 100-240 VAC, 50-60 Hz, 20 A
protected power source using a power supply cord with a C19 coupler and either
a NEMA 5-20 plug (125 V) or NEMA 6-20 plug (250 V).
Other regions — Connect the equipment to a 200-240 VAC, 50-60 Hz power
source using a power supply cord with a C19 coupler and a plug configuration of
7 A minimum.
If the unit is off, momentarily pressing this switch powers it on.
If the unit is on, pressing and holding this switch for approximately 5 seconds
powers it down.
NOTE: If you are logged into the Quantum Ultra Series device operating
system, a momentary press of this switch powers off the device.
SIG
LINK
SIG
LINK
SIG
LINK
SIG
OVER TP
OVER TP
OVER TP
Tx Rx
G Tx
Rx
Tx Rx
G Tx
Rx
Tx Rx
G Tx
Rx
OUT 1
OUT 2
OUT 3
OUT 4
USB CONFIG control connector
F
RS-232 control connector
G
LAN connectors A and B
H
Input and output card slots
I
QUANTUM IN4HDMI
QUANTUM IN4HDMI
QUANTUM OUT4HDMI
I I I
QUANTUM OUT4HDMI
QUANTUM OUT4DTP
LINK
OVER TP
Tx Rx
G Tx
Rx
DTP
DISCONNECT POWER
CORD BEFORE
SERVICING
17