Power Input; Circuit Breaker - Extron electronics IPL EXP PDU4H Setup Manual

Hide thumbs Also See for IPL EXP PDU4H:
Table of Contents

Advertisement

Cabling and Features
Attach cables using the following wiring diagrams as a guide. Full details are available in the IPL EXP PDU4H User Guide.
CAUTION:
ATTENTION :
Always use the power cord provided with the unit.
Veillez à toujours utiliser le câble d'alimentation fourni avec l'unité.
Should you need to use a different power cord, consult Extron Electronics prior to using the cord.
Si vous devez utiliser un autre câble d'alimentation, contactez Extron Electronics avant d'utiliser ce câble.

Power Input

After connecting cables to the other ports, connect a cable from the 120 VAC or 240 VAC, 50-60 Hz mains power source to this
IEC plug.
Rear Panel
100/240V ~ 12/10A MAX
BREAKER
KER
R
50-
50-60Hz
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
0-60
-60
-6
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-60
-6
-60
-60
-60
60
60
H
H
H
H
H
H
H
H z
H
H
H
H
H
H
H
H
H
H
Connect to
mains power.
ATTENTION:
Connect the equipment only to a nominal 120 VAC or 240 VAC electrical supply source.
Veillez à ne connecter le dispositif qu'à une source d'alimentation nominale de 120 Vca ou 240 Vca.
Output voltage follows input voltage. Connect the equipment to a supply voltage suitable for the load equipment.
La tension de sortie suit la tension d'entrée. Connectez l'équipement à une tension électrique adaptée à l'équipement
de charge.
The equipment must be connected to an earthed mains socket-outlet.
L'équipement doit être connecté à une prise électrique avec mise à la terre.

Circuit Breaker

The rear panel features a 12 A rated circuit breaker. When a fault condition occurs, the breaker is triggered, which
stops power output. Any attempt to control the AC outputs is ignored while the fault condition is present. The front
panel Breaker LED lights. This condition can be monitored and the system can be configured (using available
commands) to send an alert e-mail or perform some other action. After you correct the cause of the overcurrent
condition, press the Breaker button to manually reset the circuit breaker and turn off the LED. The AC power ports
remain off until they are manually turned on. This prevents inadvertent damage to equipment after an overcurrent
condition when the user resets the switch before the condition is cleared.
1
1
1
Power Input
• Connect to
• Front panel LED (
120 or 240 VAC,
blinks during boot-up
50-60 Hz.
and remains lit when
the IPL EXP receives
power.
Front Panel
)
R
Power and
Reset LED
CAUTION:
Always
disconnect the
product from the
wall plug.
ATTENTION :
Veillez à toujours
déconnecter le
produit de la
prise murale.
BREAKER
5