6.4.4 CONFIG Specifications
The following user constants can be reset in CONFIG (equipment setup) command for
SGD-jjjN.
Cn-0001
Cn-0002
Cn-0011
6.4.5 ALM_RD Specifications
Byte
Command
1
ALM RD
2
3
4
5
ALM RD MODE
6
7
8
9
10
11
12
13
14
15
16
WDT
ALM_RD_MODE
0
1
Note Alarm and warning history occurrences are saved on EEPROM, and will not be
lost if power turns OFF.
Memory switch 1
Memory switch 2
No. of encoder pulses
Response
The ALM_RD_MODE at the fifth byte of ALM_RD
ALM RD
(read alarm/warning status) is the field used to select
ALARM
objects that will be read, and it can be specified for
STATUS
each products.
ALM RD MODE
The following table shows the ALM_RD_MODE
specifications for the SGD-jjjN.
ALM DATA
RWDT
Description
Read current alarm/warning status
10 items max. (sixth to fifteenth bytes)
Read alarm/warning status history
10 items max. (sixth to fifteenth bytes)
6 -11
6.4 Special Descriptions
6