4.4 Connecting an Incremental Encoder

4.4.1 Typical Example

1MCCB
From previous
MECHATROLINK station
To next MECHATROLINK
station
External latch signal
Zero point return deceleration LS
Reverse drive prohibited when N-LS is open
Forward drive prohibited when P-LS is open
1Ry OFF with servo alarm
2Ry OFF with servo ready
Note 1. Maximum capacity of each output circuit is 50 mA and 30 VDC.
2. Signal output line
3. The 24 VDC power (I/O power) supply must be supplied by the user.
4. The power supply must be ON while the servo alarm (1Ry) remains OFF till the communication
connection (CONNECT command) is completed after the control power is turned ON.
R
T
Single phase 200 to 230 VAC
50/60 Hz
Noise filter eliminates external noise.
Noise filter
1Ry
ON
Power supply
OFF
1MC
1Ry
R
1MC
1MC
T
SGD-jjjN SERVOPACK
3CN
S
2
/
P
1
S
1
SH
3
Terminal
S
7
resistor
P
/
6
S
8
SH
120 kΩ
4
R
End of last
FG
5
station
1
CN
3.3 kΩ
+24V
+24V
6
/
P
EXT
10
7mA
/
DEC
0
9
V
N−LS
N−OT
8
7
P−LS
P−OT
30 VDC
50 mA max.
1Ry ALM
3
+24V
4
ALM−SG
P
0
V
2
Ry
/BK
1
2
BK−SG
Output capacity (Note 1)
Maximum operating voltage: 30 VDC
Maximum operating current: 50 mA
26
FG
represents twisted-pair wires.
P
Figure 4.2
Ex.: SGD-jjjN SERVOPACK Connection to Motor and Peripheral
Device
4 -5
4.4 Connecting an Incremental Encoder
+10
Single phase 100 to 115 VAC
%,
-15
50/60 Hz
Servo alarm display
For power supply OPEN/CLOSED
PL
1MC
Attach a surge suppressor to the
magnetic contactor and relays.
SUP
U
1
V
2
W
3
4
Must be grounded.
Less than 100 Ω .
2CN
Correctly terminate the
end of the shielded cable.
/External latch signal
/Zero point return
deceleration LS
Reverse drive prohibited
Forward drive prohibited
Servo alarm
Brake interlock
+10
%,
-15
Servomotor
M
Incremental
encoder
PG
4