Bosch rexroth Nexo Manual page 93

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

3 608 870 A47
MID 0018
Select tightening program
Sent by: superordinate computer
Select tightening program
Note: Program selection signals must be listed in the PLC assignment table in the OP module.
Revision: 001
Data field: tightening program number, 3 ASCII characters (000–999), 3 bytes
Possible responses
Command accepted
Command error
MID 0019
Make the presetting for OK/NOK counter
Sent by: superordinate computer
This message sets the presetting for the OK counter and the NOK counter of the Automatic operating mode
(parameter "OK counter limit") for the counter value specified in the command ("Tightening program number"
parameter)
Note: -
Revision:
Data field: Data 7 bytes
Possible responses
Command accepted
Command error
MID 0019 revision 001
Table 7–15:
Parameter
Tightening program number
OK counter value
Data length revision 001
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
MID
0005
0004
001, 002
MID
0005
0004
MID 0019 revision 001
Comments
The value consists of three ASCII characters.
ID
Value range
Presetting
Example:
Tightening program number
Value
The value consists of two ASCII characters.
ID
Value range
Presetting
Example:
OK counter value
Value
Tightening Technology | Bosch Rexroth AG
Error no. Comment
03
Tightening program cannot be selected
Error no. Comment
01
Invalid data
-
000 – 999
-
3
003
-
00 – 99
-
9
09
93/279
Bytes
3
2
5