3.3

Connection options of the Nexo cordless Wi-Fi nutrunner

Below, various connection options for the use of the Nexo cordless Wi-Fi nutrunner are described:
3.3.1

Result storage without radio connection

As of Nexo firmware version 1100, the results data can be stored in the "standard Nexo" format as a *.json
file on the NX-SD Micro SD card inserted in the nutrunner. Using the NX-A programming adapter, the
results data stored on the NX-SD Micro SD card can be viewed. The NX-SD Micro SD card can also be
accessed using a commercially available Micro SD card reader.
Settings in the NEXO-OS operating system:
D
Fig. 3–8:
(1)
(2)
Result storage without radio connection (page 34)
Results storage via WLAN: (page 35)
Control via VW-XML master PC (page 37)
PLC control and result storage via WLAN (page 38)
Fieldbus control and result storage via WLAN (page 39)
Process Quality Manager (PQM) (page 40)
As of Nexo firmware version 1200: The directory for filing of the results on the NX-SD Micro SD card
can be defined under Settings  Data  Standard Nexo  NX-SD card.
Go to the menu Help  Access to NX-SD card to access the Micro SD card. The results data are
stored in directory results.
Result storage without radio connection
IPC (industrial computer), laptop or database server
NX-A programming adapter
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
3 608 870 A47