Bosch Rexroth AG | Tightening Technology
236/279
9.8.7

PLC signals

Settings  PLC signals
Use this menu item to create a PLC assignment table. The assignment table describes the assignment of
the PLC signals to inputs and outputs.
Table 9–83:
Element
Inputs/outputs
Control signals/status signals
BmwTpc
oprt
vwXml
Activate
Deactivate
Save
Discard
Restore defaults
PLC signals tab
cl
Description
The input signals are on the left side of the window and the output signals on
the right.
The signal list shows all of the signals available.
– Already assigned and no longer available signals in the signal list will be
gray.
– Each input signal can only be assigned once. Each output signal can be
assigned up to a maximum of four times.
Inserts a signal highlighted in the signal list in the selected insert position of
the assignment table.
Removes the highlighted signal from the assignment list.
PLC signals from BMW-TPC - PLC module BmwTpc
PLC signals from Rexroth Open Protocol - PLC module oprtcl
PLC signals of the nutrunner - PLC module tool
As of Nexo firmware version 1300. If the nutrunner is in manual mode, the
Prg0-Prg7 signals can no longer be applied.
PLC signals of VW-XML - PLC module vwXml
Click Activate to activate the PLC signals of the module selected.
Click Deactivate to deactivate the PLC signals of the module selected.
Click Save to save the edited data.
Click Discard to discard the edited data.
All settings in this tab are reset to the factory setting.
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-
3 608 870 A47