Bosch rexroth Nexo Manual page 87

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

3 608 870 A47
Meanings of the individual values:
MID 0003
Communication stop
Sent by: superordinate computer
Ends the command connection.
Note: After this command has been received, the tightening controller will only respond to the communication start
command (MID 0001).
Revision: 001
Data field: is empty, 0 bytes
Possible response
Command accepted
7.5.3.3
Request responses
MID 0004
Command error
Sent by: Tightening controller
The tightening controller uses this message if a request cannot be fulfilled for some reason.
Note: -
Revision:
Data field: Data 6 bytes
Possible response: none
Table 7–10:
Parameter
MID
Error number
Data length revision 001
Example:
The select tightening program request (MID 0018) has failed, as the tightening program number did not
exist in the tightening controller.
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
01: Cell ID
0003: Cell ID value
02: Channel number
04: Channel number value
03: ID Controller name
Tightening channel
04: Manufacturer code ID
BRC: Manufacturer code fixed value
001
MID 0004 revision 001
Comments
MID of the failed request
ID
Value range
Presetting
Example:
MID
Value
Possible error numbers
ID
Value range
Presetting
Example:
Error number
Value
Tightening Technology | Bosch Rexroth AG
: Controller name value
MID
Error no. Comment
0005
-
0000 – 9999
-
18
0018
-
00 – 99
-
2
02
87/279