Bosch rexroth Nexo Manual page 102

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

Bosch Rexroth AG | Tightening Technology
102/279
Table 7–21:
Parameter
Number of defined
OK tightenings in the job
Actual value OK tightenings in
the job
Time stamp
Data length revision 002
MID 0035 revision 002
Comments
Number of OK tightenings defined in the job.
The value consists of four ASCII characters.
ID
Value range
Presetting
Example:
Number
Value
Indication of the actual value of OK tightenings in the job. The job is
completed when the actual value counter for OK tightenings
corresponds to the number of defined OK tightenings.
The value consists of four ASCII characters.
ID
Value range
Presetting
Example:
Actual value
counter
Value
Date and time of the job info message.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS
ID
Value range
Presetting
Example:
Date/time of the
job
Value
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
04
0000 – 9999
-
4
0004
05
0000 – 9999
-
4
0004
06
0 - 9, - and :
-
2019-08-01:14:35:57
2019-08-01:14:35:57
3 608 870 A47
Bytes
2
4
2
4
2
19
45

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents