3 608 870 A47
Table 7–42:
Parameter
Tool ready status
Time
Data length revision 001
MID 0077
System error status acknowledgement
Sent by: superordinate computer
Acknowledgement for MID 0076
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible response: none
MID 0078
Acknowledge system error in tightening controller
Sent by: superordinate computer
Class 3 errors can be acknowledged by the superior computer with this message.
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible responses
Command accepted
Command error
7.5.3.10
Time messages
MID 0080
Time on the tightening controller request
Sent by: superordinate computer
Time on the tightening controller request
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible response
Upload time
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
MID 0076 revision 001
Comments
Only NOK if error comes from tool.
– 1: OK
– 0: NOK
The value consists of one ASCII character.
ID
Value range
Presetting
Example:
Tool ready status OK
Value
Date and time when the error occurred.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID
Value range
Presetting
Example:
Time
Value
MID
0005
0004
MID
0081
Tightening Technology | Bosch Rexroth AG 141/279
04
0 – 1
-
1
05
0 – 9, "-" and ":"
-
1/12/2009:11:54:29 AM
1/12/2009:11:54:29 AM
Error no. Comment
58
No system error available
01
Invalid data
Error no. Comment
Bytes
2
1
2
19
36

Hide quick links: