Bosch rexroth Nexo Manual page 198

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

Bosch Rexroth AG | Tightening Technology
198/279
Tightening
Table 9–31:
Element
Tool display text
Enable tool
Tightening program
Conditional blocking of the loosen
program
Timeout options
Table 9–32:
Element
Timeout
Error message
Single program dialog - tightening panel
Description
You can save a text for all steps. The text will be displayed on the tool display.
Enable nutrunner is activated (display only): The nutrunner is enabled in this
step.
– Program no.
Defines the tightening program that is to be processed next in this stop
step. Integer values between 0 and 255 (tightening programs 0-255) are
valid characters.
– Max. OK
Defines the maximum number of OK tightening operations for this
tightening program. Integer values between 0 and 255 are valid
characters.
– Max. NOK
Defines the maximum number of NOK tightening operations for this
tightening program. Integer values between 0 and 255 are valid
characters.
– after OK result
Blocks the loosen program no. 99 after an OK tightening.
– after NOK result
Blocks the loosen program no. 99 after a NOK tightening.
– before starting the execution
As of Nexo firmware version 1400: Blocks the loosen program no. 99
before execution of the single program step.
Single program dialog - timeout options panel
Description
Enter the maximum time span when an event has to take place. If no event
occurs in this time, the step is terminated.
Enter an error message that will be displayed on the tool display after the
timeout.
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-
3 608 870 A47

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents