The Value Consists Of 19 Ascii Characters; Value Range 0 - 9, "-" And; Presetting; Example - Bosch rexroth Nexo Manual

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

3 608 870 A47
Table 7–31:
Parameter
Angle (A)
Time stamp
Date/time of the last change
OK/NOK counter status
Tightening ID
Data length revision 001
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
MID 0061 revision 001
Comments
The value is output in degrees.
The value consists of five ASCII characters.
ID
Value range

Presetting

Example:

Angle (A)
Value
Date and time of the tightening.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID
Value range
Presetting
Example:
Time stamp
Value
Date and time of the last change in the tightening program settings.
The value consists of 19 ASCII characters in the format
YYYY-MM-DD:HH:MM:SS.
ID
Value range
Presetting
Example:
Date/time of the
change
Value
Status of the OK/NOK counter.
– 0: if not 1 or 2
– 1: Ch x.y CntOK = 1
– 2: OK/NOK counter not used (not configured)
The value consists of one ASCII character.
ID
Value range
Presetting
Example:
OK/NOK counter
status
Value
With an activated OP, consecutive number for each tightening result (for
further information, see

The value consists of ten ASCII characters.

ID
Value range
Presetting
Example:
Tightening ID
Value
Tightening Technology | Bosch Rexroth AG 117/279
19
00000 – 99999
-
60
00060
20
0 – 9, "-" and ":"
-
1/12/2009:2:43:57 PM
1/12/2009:2:43:57 PM
21
0 – 9, "-" and ":"
-
1/12/2009:2:43:57 PM
1/12/2009:2:43:57 PM
22
0 – 2
-
OK/NOK counter not used
2
MID
0064).
23
0000000000 – 9999999999
-
123456
0000123456
Bytes
2
5
2
19
2
19
2
1
2
10
211