Bosch rexroth Nexo Manual page 147

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

3 608 870 A47
MID 0411 revision 001
Table 7–45:
Parameter
AutoDisable status
OK/NOK counter value
Data length revision 001
7.5.3.14
PLC output signal messages
MID 0500
Subscription Output signal change
Sent by: superordinate computer
As a consequence of this message, the superior computer is informed about every change in the configurable output
signals at the OP PLC module by means of a message (upload change in output signals,
logon (command accepted,
output signals,
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible response
Command accepted
Command error
MID 0501
Upload Output signal change
Sent by: Tightening controller
The assignment of the output signals at the OP PLC module has changed.
Note: -
Revision:
Data field: Number of signals, 8 bytes or 16 bytes
Possible response
Acknowledgement Upload output signal
change
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
MID 0411 revision 001
Comments
Status of the automatic disable on option Disable when OK/NOK
number is reached at OK/NOK counter
Possible values:
– 00: not selected
– 01: selected
The value consists of two ASCII characters.
ID
Value range
Presetting
Example:
AutoDisable
status
Value
Fixed value 00
Fixed value
MID
0005), the tightening controller moreover sends a message (upload change in the
MID
0501) with the current assignment of the output signals to the superior computer.
MID
0005
0004
001, 002
MID
0502
Tightening Technology | Bosch Rexroth AG 147/279
-
00 – 01
-
Not set
00
00
Error no. Comment
86
Activation for output signal change already available
Error no. Comment
Bytes
2
2
4
MID
0501). After confirmed