3 608 870 A47
7.5.3.8
Messages on tightening results
MID 0060
Last tightening results data subscription
Sent by: superordinate computer
Tightening results data subscription
Note: -
Revision: see
Data field: is empty, 0 bytes
Possible responses
Command accepted
Command error
MID 0061
Upload last tightening results data response
Sent by: Tightening controller
Upload last tightening results data response
Note: Revision 999 is intended for superordinate computers with a limited receive capacity (small receive buffer). In
order to limit the size of the MID 0061 as much as possible, the parameter IDs that would usually be sent in the
message have been removed.
Revision:
Data field: Data 211 bytes (revision 001), 365 bytes (revision 002), 399 bytes (revision 003),
480 bytes (revision 004), 101 bytes (revision 999)
Possible response
Last tightening results data
acknowledgement
MID 0061 revision 001
Table 7–31:
Parameter
Cell ID
Channel ID
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
MID 0061
MID
0005
0004
001, 002, 003, 004, 005, 999
MID
0062
MID 0061 revision 001
Comments
This is where the 7th level of the location name is returned.
The value consists of four ASCII characters.
ID
Value range
Presetting
Example:
Cell ID
Value
The first two characters of a channel name are used as channel ID. A
channel name consists of the channel ID and the name of the controller,
both of which are separated by a space.
The value consists of two ASCII characters.
ID
Value range
Presetting
Example:
Channel ID
Value
Tightening Technology | Bosch Rexroth AG 113/279
Error no. Comment
09
Activation for the last tightening result already
available
Error no. Comment
01
0000 – 9999
-
21
0021
02
01 – 20
01
04 tightening channel
04
Bytes
2
4
2
2