Bosch rexroth Nexo Manual page 140

Cordless wi-fi nutrunner
Hide thumbs Also See for rexroth Nexo:
Table of Contents

Advertisement

Bosch Rexroth AG | Tightening Technology
140/279
MID 0075
Acknowledgement System error in tightening controller acknowledged
Sent by: superordinate computer
Acknowledgement for MID 0074
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible response: none
MID 0076
System error status
Sent by: Tightening controller
The system error status is sent after a subscription for system errors from the tightening controller has been accepted.
Note: The system error status informs the superior computer that a system error is currently active in the connected
controller. Exactly one system error status message is sent for each active system error in the connected controller.
Revision:
Data field: Data 36 bytes
Possible response
System error status acknowledgement
MID 0076 revision 001
Table 7–42:
Parameter
System error status
Error number
Controller ready status
001
MID
0077
MID 0076 revision 001
Comments
– 0: No system error active
– 1: A system error is currently active
The value consists of one ASCII character.
ID
Value range
Presetting
Example:
System error
status
Value
The value consists of four ASCII characters.
ID
Value range
Presetting
Example:
Error number
Value
Always NOK (=0), as no differentiation is made between controller and
tool.
The value consists of one ASCII character.
ID
Fixed value
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
Error no. Comment
01
0 – 1
-
A system error is active
0
02
0000 – 9999
-
105
0105
03
0
3 608 870 A47
Bytes
2
1
2
4
2
1

Hide quick links: