3 608 870 A47
Table 9–80:
Element
Next check
Last check
Output drive
Tag ID
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2019-10
Configuration tab
Description
The angle head rotation can be adjusted in increments of 1° between 0° and
360°. Select the appropriate setting of the angle head.
NXA011S, NXA015S: The angle head can be adjusted in increments of 45°
from 0°, 45°, 90°, 135°, 180°, 225°, 270° to 315°.
NXA030S, NXA050S, NXA065S: The angle head is continuously
adjustable by 360°. For precise definition of the angle head position, please
use the angle setting gauge NXAHPG.
– Activated
Yes: Check enabled
No: Check disabled
If in active monitoring, the set limits are reached in the next check, the
controller sends the PLC output signal CheckTool (
enters a class 0 system error. The PLC signal is reset if one of the following
events occurs:
– Cycle
Enter the cycle during which the check is to be carried out.
– Date
Date for the next check.
– Date
Enter exactly when the check was carried out.
– Cycle
Enter exactly in which cycle the check was carried out.
– Order number
Component order number
– Serial number
Component serial number
– Efficiency
Enter the efficiency
– Transmission
Enter the transmission
As of Nexo firmware version 1400:
Input of tag identification, max. 20 characters.
Tightening Technology | Bosch Rexroth AG 233/279
Nutrunner display
90°
45°
360°
(see page